Fast-curing, 100% solids Novolac epoxy compound, ceramic-filled and reinforced with aramid fiber matrix, offering resistance to abrasion and impact. Good chemical resistance in the presence of caustics and acids. Suitable for temperatures up to 280°C. Easily applied with a trowel, spatula, or by hand using latex gloves.
| Maximum Temperature (Dependent on service) | Wet Service | Dry Service | 230°C | 280°C | 446°F | 536°F |
|---|---|---|---|
| Solids by Volume | 100% | ||
| Viscosity | Paste | ||
| Mixed Density | 2.0 | ||
| Shore D Hardness | (ASTM D 2240) | 84 | |
| Pot Life | 25 min / kg at 72ºF | ||
| SAG Vertical Resistance at 21ºC (70ºF) and 6mm (240mils) | No sagging | ||
| Mix Ratio | 2:1 by Weight | Base: Activator | |
| Shelf life (unopened containers) | 3 years at 55-95ºF (13-35ºC) | ||
Surface Preparation
Proper surface preparation is essential for the long-term performance of this product. The exact surface preparation requirements vary depending on the severity of the application, expected service life, and the initial condition of the substrate. All sharp edges and welds must be ground to a 3 mm (120 mil) radius using an abrasive disc. Optimal preparation will result in a thoroughly clean surface, free of all contaminants, and roughened to an angular profile between 75–125 μm (3–5 mils).This is typically achieved through initial cleaning and degreasing, followed by abrasive blasting to a near-white metal finish, or by mechanical preparation.
Mixing
Thoroughly mix the activator into the base using a mixing stick, scraping the sides and bottom of the container. Mix at a ratio of 2 parts Base to 1 part Activator by weight. Blend thoroughly until a uniform, streak-free material is achieved. Never add solvents.
Application
Use heavy plastic squeegee or putty knife to apply a 3mm minimum thickness. Work material into profile of substrate to achieve maximum adhesive and to remove any entrapped air. Contour to correct form with putty knife or plastic applicator. If mold or form is used be sure to coat its surface with a release agent to prevent adhesion of the material.
Application Temperature: Keep between 55 to 95ºF (17 to 35ºC). Substrate: keep between 45 to 105ºF (7 to 40ºC). the difference in temperature of the substrate and the material should never exceed 10ºF, 5ºC. Substrate shall be a minimum of 5ºF (3ºC) above dew point. Do not apply if relative humidity exceeds 90%. If necessary, heat the metal prior to surface preparation using electric heater or heat lamp. Never use gas, oil or kerosene heaters as they will leave a greasy residue on metal surface. For best results keep all material in warm area overnight (75ºF+) for ease of mixing.
Cured Time:
| 16°C (60°F) | 25°C (77°F) | 32°C (90°F) | |
|---|---|---|---|
| Tack Free | 45 min. | 30 min. | 20 min. |
| Light Load | 1 hour | 45 min. | 30 min. |
| Overcoat End | 1 hour | 45 min. | 30 min. |
| Full Load | 1.5 hours | 1 hour | 45 min. |
Clean
Tools should be thoroughly cleaned immediately after use with a strong alkaline detergent.
Safety
Before using any products, review the appropriate Safety Data Sheet (SDS) or Safety Sheet for your area. Follow standard confined space entry and work procedures, if appropriate.
The manufacturer, Taurus Epoxy Inc., makes no express or implied warranties, including warranties of merchantability or fitness for a particular purpose for this product. Under no circumstances shall the manufacturer be liable for incidental, consequential or other damages, breach of warranty, strict liability or any other theory arising from the use of this product. The information and recommendations contained herein are based on the Standard Product and are owned and provided solely for the use of our customers. This information is provided in good faith and is believed to be true and accurate as of the date/version of this document. As the manufacturer has no control over the conditions of use or the application process of the parts using this product, the manufacturer cannot accept responsibility for loss, injury or other damage resulting from the use of the Product or this or any other information provided by the manufacturer. Therefore, no warranties of any kind, express or implied, are made by the manufacturer, Taurus Epoxy Inc., with respect to this, or any, product manufactured by them or any contracted or licensed manufacturer. Taurus Epoxy products do not provide structural integrity or improvements. They are only used to provide protection against corrosion, wear, abrasion and chemical attack on a given substrate and only to the extent provided for in data sheets, data sheets, safety data sheets and any other information provided in writing directly from manufacturers’ technical support.